產品介紹

直流電源供應器
  • Facebook
  • LINE
  • Twitter
  • LinkedIn
SGA / SGI Series - Sorensen  (5k-30kW) modular programmable DC power supply | 洛克Lockinc
功能說明

Sorensen SG Series (SGA/SGI)
(5k-30kW) modular programmable DC power supply with exceptional load transient response, low noise and high power density

Product Overview

The Sorensen SG Series (hereafter SG Series) represents the next generation of high power programmable DC power supplies. The SG Series is designed for exceptional load transient response, low noise and the highest power density in the industry. With a full 15 kW available down to 20VDC output in a 3U package the SG leads the industry in power density. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. 
At the heart of the SG series is a 5 kW power module. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. Combinations of these chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features.

◎ SGI: Advanced Intelligent Control

(Sorensen General purpose Intelligent) The SGI combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI.

◎ SGA: Outstanding Value - Analog Control

(Sorensen General purpose Analog) The SGA, with its industry leading performance, is available for customers requiring simple front panel analog controls or external control. With the same high performance power electronics as the SGI, the SGA provides essential features like 10- turn potentiometers for setting voltage and current, 3 ½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.
 

SGI / SGA Comparison Chart
Feature SGA SGI
Modular Design
Fast Load Transient
Parallelable
Analog & Digital Summing Optional
Direct Front Panel V/1 Control
3½ Digit LED Readout
Graphics Display
Sequencing
Save / Recall Setups
System Power Readouts
Constant Power Mode
IEEE-488.2/RS-232C Optional RS-232C Std IEEE-488.2 Optional
LXI Class C Ethernet/ RS-232 Optional RS-232C Std, Ethernet Optional
Front Panel Dust Filter Optional (3U unit only) Optional (3U unit only)
Applications
Burn-In Compliance Testing
Materials Research Process Control
Product Validation Automotive Electronics
Rackmount ATE Systems Battery Charging
See the SFA product page for very high current slew rate and low stored energy applications.
規格說明
Common
Remote Sense Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40 - 100V models, line drop 1V of rated voltage per line for 10 - 20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. ( Greater line drop is allowed, but output regulation specifications no longer apply ).
Parallel Operation Up to 5 units may be paralleled for additional current within the power supply single - unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
Series Operation Up to 2 units ( see Output Float Voltage )

Input
Nominal Voltage
3 phase, 3 wire +
ground
208/230 VAC ( operating range 187 - 253 VAC )
380/400 VAC ( operating range 342 - 440 VAC )
440/480 VAC ( operating range 396 - 528 VAC )
Frequency 47 – 63Hz , 400Hz ( 400Hz @ 208VAC, for 6U units is optional modification and does not carry CE, UL or CSA markings )
Power Factor >0.9 typical for 10V - 30V, 50V, 1000V and other models with optional “PF” modification.
>0.75 typical for 208/220 VAC input (40V, 60V - 800V models, 0.9 available with modification “PF”)
>0.72 typical for 380/480 VAC input (40V, 60V - 800V models, 0.9 available with modification “PF”)
>0.69 typical for 440/480 VAC input (40V, 60V - 800V models, 0.9 available with modification “PF”)
Protection ½ cycle ride-though , typical, on all three phases, 3 cycle ride through on single phase; missing phase shutdown ( 800V model 6.4 msec on all 3 phases )

Programming & Read-back Specifications ( with sense wires used )
Programming Read-Back / Monitoring
Accuracy Resolution Accuracy Resolution
Front panel Display SGA : +/- ( 0.5%fs + 1 digit) SGI (40-1000V ) +/- 0.1% of voltage at full scale SGI ( 40-1000V ) +/- 0.4% of current at full scale SGA : 3.5 digits SGI : 4.0 digits SGA : +/- ( 0.5%fs + 1 digit ) SGI, Voltage : +/- 0.1% of full scale SGI, Current: +/- 0.4% of full scale SGA : 3.5 digits SGI : 4.0 digits Knob control & Display read - back
SGI ( 10 - 30V ) 0.1% of set point +0.1% of voltage rating SGI ( 10 - 30V ) 0.1% of set point + 0.4% of current rating SGI ( 10 - 30V ) 0.1% of actual +0.15% voltage rating
Remote Analog Interface Voltage +/-0.25% of full scale Current ( 40 - 1000V ) 0.8% of full scale , ( 10 - 30V ) 1.0% of full scale N/A ( 40 - 1000V ) +/-1.0% of full scale N/A 25 - pin D - sub connector ( 0~5 V or 0~10 V )
( 10 - 30V ) +/-0.5% of full scale
Remote Digital Interface Voltage : +/- 0.1% of full scale, Current: +/- 0.4% of full scale +/-0.002% of full scale Voltage : +/- 0.1% of full scale Current : +/- 0.4% of full scale +/-0.002% of full scale RS - 232C ( Standard on SGI ), Optional IEEE - 488.2 and Optional LXI Compliant 10/100 base - T Ethernet ( see Options )
OVP +/- 1% of full scale +/-0.002% of full scale Programming range : 5 - 110% Configured from front panel, remote analog or via optional digital inputs
User I/O Disconnect & Polarity - reversal relay control
( Only available with Ethernet Option )
Digital 10 - pin Molex type connector Chart Below
Software IVI & CVI drivers available under DOWNLOADS at :
www.ProgrammablePower.com

Physical
3U Models (10V-30V) 3U Models (40V-1000V) 6U Models (60V-600V)
Width 19.00 in ( 48.3 cm ) 19.00 in ( 48.3 cm ) 19.00 in ( 48.3 cm )
Depth 28.09 in ( 71.35 cm ) 26.4 in ( 67.1 cm ) 27.06 in ( 68.8 cm )
Height 5.25 in ( 13.3 cm ) 5.25 in ( 13.3 cm ) 10.5 in ( 26.7 cm )
Weight ( 4kW, 10V 15V ) ≈<65 lbs ( 29 kg )
( 5kW, 20V 30V ) ≈<65 lbs ( 29 kg )
( 8kW, 10V 15V ) ≈<85 lbs ( 39 kg )
( 10kW, 20V 30V ) ≈<85 lbs ( 39 kg )
( 12kW, 10V 15V ) ≈<110 lbs ( 50 kg )
( 15kW, 20V 30V ) ≈<110 lbs ( 50 kg )
( 5kW ) ≈ ≤60 lbs ( 27 kg )
( 10kW ) ≈ ≤75 lbs ( 34 kg )
( 15kW ) ≈ ≤90 lbs ( 41 kg )
( 20kW ) ≈ ≤140 lbs ( 64 kg )
( 25kW ) ≈ ≤155 lbs ( 71 kg )
( 30kW ) ≈ ≤170 lbs ( 78 kg )
Shipping Weight Contact factory for more product & shipping weights

Output
Ripple & Noise
( Voltage Mode, Typical )
See Output : Voltage & Current Ranges Chart above. Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1μf at load
Ripple ( Current Mode ) <+/- 0.04% of full scale rms current
Output Rise Time
( 40 - 800V )
≈< 100 ms 5 - 95% of full scale typical - resistive load ( Contact factory for model specific slew rates )
Output Rise Time
( 10 - 30V )
Rise Time, ms, MAX Condition
10 Measured from 10% to 90% of the output voltage change - resistive load, typical
Output Voltage Fall Time ( 10 - 30V ) Fall Time, MS MAX Condition
No Load 1  50 100% CC Load 10 100% CR Load 10 Measured from 90% to 10% of the output voltage change. - resistive load, typical
Output Current Rise Time ( 10 - 30V ) Rise Time, ms, MAX Condition
20 Measured from 10% to 90% of the output current change - resistive load, typical
Output Current Fall Time ( 10 - 30V ) Rise Time, ms, MAX Condition
10 Measured from 10% to 90% of the output current change - resistive load, typical
Line Regulation
( with sense wires used )
( ±10% of nominal AC input, constant load )
Voltage Mode : +/- 0.01% of full scale ( 40 - 800V )
Current Mode : +/- 0.05% of full scale ( 40 - 800V )
Voltage Mode and Current Mode : +/- 0.05% of full scale ( 10 - 30V )
Load Regulation
( with sense wires used )
( no load to full load, nominal AC input )
Voltage Mode : +/- 0.02% of full scale ( 40 - 800V )
Current Mode : +/- 0.1% of full scale
Voltage Mode : +/- 0.05% of full scale ( 10 - 30V )
Load Transient Response Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
Efficiency 87% typical at nominal line and max load
Stability ±0.05% of set point after 30 minute warm - up and over 8 hours at fixed line, load and temperature, typical
Temperature Coefficient 0.02%/ C of maximum output voltage rating for voltage set point, typical
0.03%/ C of maximum output current rating for current set point, typical
Output Float Voltage Negative terminal within +/- 300 V of chassis potential.
( We recommend the use of optional isolated analog Interface ( IAI ). )
Supplies in "series" should be the same output voltage/current, in not system current is limited to lower of the two supplies.

Common
Operating Temperature 0 to 50º C
Storage Temperature -25º C to 65º C
Humidity Range Relative humidity up to 95% non-condensing, 0º C – 50º C
Altitude Operating full power available up to 5,000 ft. ( ~1,500 m ), derate 10% of full power for every 1,000 feet higher; non - operating to 40,000 ft. ( ~12,000 m )
Cooling Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant. LVD Categories : Installation Category II : Pollution Degree 2; Class II Equipment : for Indoor Use Only, back panel not user accessible ( see user manual for installation instructions ) EMC Directive, EN 61326 : 1998
Front Panel Dust Filter 30 PPI ( Pores Per Inch ) - must ensure adequate airflow and / or derate max. temperature. 3U unit only.

Output: Voltage and Current Ranges
3U
Power 4/5 kW 8/10 kW 12/15 kW
Voltage Current
10 400 800 1200
15 267 534 801
20 250 500 750
30 167 334 501
40 125 250 375
50 100 200 300
60 83 167 250
80 63 125 188
100 50 100 150
160 31 63 94
200 25 50 75
250 20 40 60
330 15 30 45
400 12 25 38
500 10 20 30
600 8 17 25
800 6.2 12.5 18.7
1000 5 10 15

Output: Voltage and Current Ranges
6U
Power 16/20 kW 20/25 kW 24/30 kW
Voltage Current
10 1600* 2000* 2400*
15 1068* 1335* 1602*
20 1000* 1250* 1500*
30 668* 835* 1002*
40 500* 625* 750*
50 400* 500* 600*
60 333 417 500
80 250 313 375
100 200 250 300
160 125 156 188
200 100 125 150
250 80 100 120
330 61 76 91
400 50 63 75
500 40 50 60
600 33 42 50
800 25* 31.2* 37.5*
1000 20* 25* 30*
* By way of paralleling 5kW, 10kW & 15kW supplies

Read-back Specifications
Ripple & Noise
Voltage rms (20Hz-300kHz) p-p (20Hz - 20MHz)
10 20mV 50mV
15 20mV 50mV
20 20mV 60mV
30 20mV 60mV
40 20mV 75mV
50 20mV 75mV
60 20mV 75mV
80 20mV 100mV
100 20mV 100mV
160 25mV 150mV
200 25mV 175mV
250 30mV 200mV
330 30mV 200mV
400 30mV 300mV
500 50mV 350mV
600 60mV 350mV
800 80mV 500mV
1000 100 mV 650 mV
* By way of paralleling 5kW, 10kW & 15kW supplies

Analog User I/O Pinouts
1 Isolated Remote ON/OFF 14 Isolated TLL / CMOS ON / OFF Control
2 Isolated Circuit Return 15 Remote Voltage Programming
3 Remote Overvoltage Set 16 Remote Current Programming
4 Voltage Return for Pins 9, 15, or 21 17 Fault State
5 Remote ON/OFF 18 Shutdown Fault
6 Circuit Common 19 Output Voltage Monitor
7 Output Current Monitor 20 Voltage Return for Pins 9, 15, or 21
8 Local Voltage Control Monitor 21 Voltage Control Resistance
9 Remote Voltage Programming 22 Current Control Resistance
10 Remote Current Programming 23 Current Return for Pins 10, 16, or 22
11 Local Current Control Monitor 24 Circuit Common
12 Not Used 25 Current Return for Pins 10, 16, or 22
13 Not Used
 
Digital User I/O Pinouts ( Ethernet Option Only )
1 Fold Back Monitor
2 Direct Shutdown
3 Fault Indication
4 Trigger Out
5 Common
6 Polarity output reversal signal
7 Isolation relay relay open signal
8 Sense relays open signal
9 Common
10 Trigger in
Loading...