產品介紹

模組化電源供應器
  • Facebook
  • LINE
  • Twitter
  • LinkedIn
AMETEK Power Chassis - ELGAR ReFlex  Distribution, cabling, I/O and power connection and rack for the ReFlex Power System | 洛克Lockinc

Power Chassis

ELGAR ReFlex Distribution, cabling, I/O and power connection and rack for the ReFlex Power System

型錄下載 (633 KB)
手冊下載 (8.4 MB)
功能說明

Product Overview

ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.

Up to 8 mainframes, potentially up to 95 modules, can be controlled via a single controller. The controller communicates to the individual modules via a high speed proprietary bus protocol, providing very high data rates and a high degree of deterministic control. The RFP™ controller communicates to the host controller via an Ethernet LAN connection designed to be compliant with the LAN Extension for Instrumentation ( ™ ) standard, assuring interoperability and ease of integration. RFP™ system modules can be combined via the controller, permitting the creation of “virtual assets” with the voltage/current combinations required for a particular test regime. Creating “virtual assets” reduces the “logistical tail” and total cost of ownership.

Available power modules include 
  • Single slot, 330 Watt programmable DC supplies
    • 16V, 20.6A
    • 65V, 5.1A
       
  • Dual slot, 1kW programmable DC supplies
    • 33V, 30A
    • 50V, 20A
    • 50V, 25A
    • 120V, 8.3A
    • 450V, 2.3
       
  • Triple slot, 875 VA, single phase, programmable AC supply
    • Dual range: 280V(rms), 3.5A(rms)
    • Dual Range: 140V(rms), 7A(rms)
       
  • Triple slot, 500V, programmable electronic DC loads
    • 15A, 375 Watt
    • 30A, 750 Watt

The mainframe provides internal power distribution, cabling, I/O and power connection and rack mounting for 12-asset slots. The mainframe also supplies the signal and control bus fabric supporting multi-module series/parallel operation, complex triggering, fault I/O and inter-mainframe control infrastructure.

Input
Universal Input AC 1 phase:115/120/200/208/230V ±10%
AC 3 phase: 115/200 or 120/208V ±10% delta and wye
AC 3 phase: 230/400V ±10% wye – neutral
AC Voltage Range: 103.5V to 253V
DC Voltage Range: 210V to 300V (314V for 2 sec.)
Power Factor: ≥0.95
Frequency range 47Hz to 63Hz, DC
Input Connector Amphenol, DL3102A24-10P or Phoneix style
Mating Connector Amphenol, DL3106A24-10P
Common
Module Interface Backplane Slot Positions: 12 slots Multi-module control interface
Configuration Guidelines Up to 8 Chassis may be interconnected. Paralleled AC, DC and Load modules must be in adjacent slots and be like modules. AC modules to be configured for multi-phase operation must be in adjacent slots.
Regulatory Certified to UL 61010-1, CSA C22.2 No. 61010.1 and
IEC/EN 61010-1.
Compliance with EN61326 and FCC 21 CFR, Subpart J
CE Mark is to EMC and LVD
All specifications are subject to change
Environmental - Common
Operating Temperature -10° C to 50° C Extended operating range available
Storage Temperature -40° C to 70 °C
Operating Humidity Range 95%, non-condensating
Altitude up to 2,000 M Extended operating range available
Shock and vibration Class 3 Mil-PRF-28800F
Physical
Dimensions EIA RS-310 rack mount : Wide
7” (177.8mm) (4U) : High
17”(432 mm) : Depth
Weight 11.4 lbs - Mainframe
Rack Mount RETMA brackets
Cooling Modules have integral fan cooling
Physical : Module Sizes
Dimensions Single Slot 1.4” (35.6mm) W
6.75” (171.5mm) H
15” (381 mm) D
Dimensions Dual Slot 2.8” (71.1) W
6.75” (171.5mm) H
15” (381 mm) D
Dimensions Triple Slot 4.2” (106.7mm) W
6.75” (171.5mm) H
15” (381 mm) D

Manuals
ReFlex Power Operation Manual Rev K - 11/9/2011 (3.64MB)
ReFlex Power Programming Manual Rev J - 11/9/2011 (1.76MB)
Tech Note: Mating Connnectors for Mainframe Rev E - 02/07/09 - 186Kb
Tech Note: Mating Connnectors for Controller Rev F - 02/07/09 - 146Kb
Tech Note: Mating Connnectors for LPDC 16V Rev E - 02/07/09 - 158Kb
Tech Note: Mating Connnectors for LPDC 65V Rev E - 02/07/09 - 153Kb
Tech Note: Mating Connnectors for HPDC 33V / 50V Rev F - 02/07/09 - 94Kb
Tech Note: Mating Connnectors for HPDC 120V Rev X2 - 03/31/09 - 92Kb
Tech Note: Mating Connnectors for HPDC 450V Rev E - 02/07/09 - 108Kb
Tech Note: Mating Connnectors for FPDC Rev E - 02/07/09 - 87Kb
Tech Note: Mating Connnectors for AC Rev D - 02/07/09 - 158Kb
Tech Note: Mating Connnectors for Loads Rev D - 02/07/09 - 99Kb
Tech Note: Fault Protection Groups Rev A - 02/07/09 - 96Kb
Tech Note: Firmware Updates Rev B - 02/07/09 - 421Kb
Quick Reference guide : Reflex Power Network Communication and Output Connections Rev E - 5/6/2010 (244KB)
Data Sheet
ReFlex Power Data Sheet 3/30/2012 (541KB)
Software
AC IVI-COM Driver (2.0.11.0) ¹ 4380277-09 3/26/2012_2.76 Mb
DC IVI-COM Driver (2.0.12.0) ¹ 4380276-10 3/26/2012  3.26 Mb
Loads IVI-COM Driver (2.0.9.0) ¹ 4380278-07 3/26/2012_2.68 Mb
Firmware Update Executable 21.2 Kb
Firmware Update V3.500 2/16/2012 (2.25MB)
ReFlex Power Control & Monitor GUI
- ElgarRAC v2.0.5.0 
- ElgarRDC v2.0.6.0 
- ElgarRLD v2.0.5.0
02/16/2010 - V1.0.0.2 - 33.7Mb
Loading...